General Errors/Warnings/Messages

General design function error conditions: 15 error conditions, 3 warning conditions, 3 messages.

General error conditions: 8 error conditions and 2 messages.

Info The formatting 'xx0' of an error, warning or message indicates the design function in which the error, warning or message occurred. For example E310 indicates the error occurred in design function 3.1.

Errors:

Exx0/80:

table 'title' invalid data (empty?)

Exx0/81:

table 'title' invalid data (no rows?)

Exx0/82:

table 'title' invalid data (no columns?)

Exx0/83:

table 'title' number of columns?

Exx0/84:

table 'title' toggled (system-error)

Exx0/85:

table 'title' n-toggled columns not correct

Exx0/86:

table 'title' idents SHPI not correct

Exx0/87:

table 'title' non exist. ident 'title'

Exx0/88:

Table 'title' empty columns not correct

Exx0/89:

Table 'title' second column < first

Exx0/90:

'Feature' not (yet) implemented

The program feature 'feature' is not yet available for customers.

Exx0/91:

Table 'title'  cannot be used

The table 'title' may have correct data, but it cannot be used because e.g. model options prohibit it.

Exx0/92:

Table 'title'  has no data

The mentioned table has no data in it, or it contains only untested data or data with errors.

Exx0/93:

Questioned table has errors

The table marked (see Overview Panel) contains data, during the calculation it was determined that the table has errors.

Exx0/94:

Function stopped due to occurring errors

Calculation of the design function was aborted because at least one error occurred that prohibited further calculations. See the Warning-table for more information.

Exx0/95:

Table 'title' contains data, but module 'X' is unavailable

The reported program module is not present in the user's license, but for using the data in the mentioned table this module is essential. Therefore, calculation is not possible until the user’s license is changed to contain the shown program module, or input data is changed in such a way that the mentioned table is empty.

Please contact EDS to acquire the missing program module.

Exx0/96:

Mod. 'X' unavail, can't calculate 'name'

The shown program module is not present in the user's license, but it is required to calculate the mentioned aspect of the project. Therefore, calculation of the design function is not possible until the user’s license is changed to contain the shown program module.

Please contact EDS to acquire the missing program module.

Exx0/97:

table 'name' NODE  'number' not in list ¹

Exx0/98:

table 'name' element  'number' not in list ¹

Exx0/99:

table 'name' ident 'name'  not in list ¹

Warnings:

Wxx0/92:

Table 'title' ignored.

No SIS, table 'title' ignored.

No tees, table 'title' ignored.

No supports, table 'title' ignored.

No joints, table 'title' ignored.

No nodal loads, table 'title' ignored.

No back tension, table 'title' ignored.

No soil, table 'title' ignored

No nonlin, table 'title' ignored

The configuration is such that the data in the mentioned table is superfluous. Therefore the data is ignored, i.e. the table is treated as if it is empty.

Wxx0/95:

Mod. 'X' unavail, table 'title' ignored

The shown program module is missing in the user's license, the data in the mentioned table is ignored, i.e. the table is treated as if it is empty.

Please contact EDS to acquire the missing program module.

Wxx0/96:

table 'name' idents not increasing ²

Wxx0/98:

Deleted connection matrix from project.

Internal error. As a consequence the current project database might run out of available space. To avoid this situation it is advisable to create a new project, copy all input data and options to it and calculate again..

Wxx0/99:

input-table(s) nd/el not in list

Messages:

Mxx0/90:

'Feature' not (yet) present

The program feature 'feature' is not yet available for customers. Note that this missing functionality does not influence the accuracy of the calculations results.

Mxx0/94:

element table 'name' toggled to nodes ²

Mxx0/95:

node table 'name' toggled to elements ²

Mxx0/99:

table 'name', coordinates not in range

Specified coordinates are beyond the configuration section considered.

Errors:

E999/1:

No core room for database+program 'tit'

E999/2:

Database not correct; copy tables

E999/3:

EDS hardware key not correct ('tittle')

E999/4:

Disk full; emergency exit

E999/6:

Educational database greater than 8 MB

E999/7:

Table too long for education database

E999/99:

Process stopped due to no response

Messages:

M999/98:

Wintertime hour added

M999/99:

Negative account changed

 

¹ A number of input tables contains data to be tested on conditions dependent on data calculated by the program. When, for example, input data at a node must be given, it is checked whether the node number specified is an existing node number. This check is not possible if design function 200 (GENERATE PIPELINE CONFIGURATION) has not been processed yet, because the number of nodes is calculated during processing of that function. Therefore the check is carried out during processing of the function in question.

² Through the TOGGLE option the NODE input column of tables NODALL and FOCUSL can be switched to an ELEM input column and the ELEM input columns of table SECTION can be switched to NODE columns. Those switches are ignored!  IDENTS may be assigned to the same node (coordinates).


H2004, last changed: 14/09/2016

See also:

Design function description

Input data table overview

Output data table overview