Data description/conditions

Data description/conditions

Specification of pipe wall thickness along pipeline axis (Input Table)

Data description/conditions:

X-P:

X-coordinate of data reference point

None / Required ¹

(X-P values should be increasing. Column may be toggled to AX-L, AX-LP, NODE, ELEM or IDENT, see toggling data tables.)

T-NOM1:

Nominal pipe wall thickness just before and at data reference point

> 0.

(The value given for T-NOM1 on the first data table line is valid for every value of X less than or equal to X-P(1))

COR-AL1:

Corrosion allowance just before and at data reference point

0. and < T-NOM1 / Undefined

(If Undefined no allowance is taken into account)

RTOL1:

Manufacturing tolerance percentage for pipe wall thickness T-NOM1

0. and < 100. / Undefined

(The wall thickness is reduced with the tolerance percentage if specified)

ATOL1:

Absolute manufacturing tolerance for pipe wall thickness T-NOM1

0. and < T-NOM1 / Undefined

(The wall thickness is reduced with the value if specified. Either RTOL or ATOL may be specified, not both.)

T-NOM2:

Nominal pipe wall thickness just after data reference point

> 0. / Undefined

(If Undefined it is assumed that T-NOM2 = TNOM1. The value given for T-NOM2 on the last data table line (n) is valid for every value of X greater than X-P(n))

COR-AL2:

Corrosion allowance just after data reference point

0. and < T-NOM1 / Undefined

(If Undefined it is assumed that COR-AL2 = COR-AL1)

RTOL2:

Manufacturing tolerance percentage for pipe wall thickness T-NOM2

0. and < 100. / Undefined

(If Undefined it is assumed that RTOL2 = RTOL1)

ATOL2:

Absolute manufacturing tolerance for pipe wall thickness T-NOM2

0. and < T-NOM2 / Undefined

(If Undefined it is assumed that ATOL2 = ATOL1)

 

¹ see also DATA CONDITIONS at TABLE ERROR DESCRIPTION


H310131, last changed: 14/09/2016

See also:

Table description

Table error description