Function errors/warnings/messages

Function errors/warnings/messages

Compose pipeline loadings

 

Function ready condition: All 'Optional' input data tables which contain data tested. If table NODALL or FOCUSL is given, table NODALS shall be present as well.

 

Function error condition: 4 error conditions, 5 warning conditions, 1 message

Errors:

E420/1:

Load name 'title' not found

The nodal load reference name LOADREF specified in input table NODALL or FOCUSL has not been specified in input table NODALS.

table LOADATA will become questioned, with field in question = [Error!]

E420/2:

More than 3 global load references - or - more than 2 local load references - or - more than 1 focus load reference

In input table NODALL or FOCUSL for a node more than the allowed number of nodal load sets have been specified in one of the coordinate systems.

table LOADATA will become questioned, with related fields NLGLOB or NLLOC or FOCUS = [Error!]

E420/3:

'setl' load component without soil

No soil has been specified in the previous function and one of the input tables SETX, SETY, SETZ or SUBSIDE is present.

table LOADATA and related input table(s) will become questioned (destroy related input table(s) or set function 320 back in order to specify soil parameters).

E420/4:

Focus node coincides with focus point

The coordinates of a node where a focus load applies are equal to the coordinates of the focus point.

table LOADATA and related input table FOCUSL will become questioned with related field FOCUS = [Error!]

(In this case the direction of the focus load is indeterminate.)

Warnings:

W420/1:

Only upward settlements

All values in table SETZ are specified positive.

(This warning is given because it may be not intended and caused by omitting the minus sign erroneously.)

W420/2:

Only upward subsidences

All values in table SUBSIDE are specified positive.

(This warning is given because it may be not intended and caused by omitting the minus sign erroneously.)

W420/3:

Subside row without resulting node value

The specification of a subsidence in a row of table SUBSIDE is such that it results in zero values at the nodes of the pipeline.

(This warning can be the result of erroneous length specification in table SUBSIDE and/or the existence of long elements.)

W420/4:

Focus loads in non-x direction

A focus load is not the FX point load from table NODALS.

(This warning is given because it concerns probably an input error. A focus load not directed to the focus point is hard to imagine.)

W420/5:

Different settlements in 'number' connects

The total settlement is different in nodes of a connection point.

(number = number of connection points with different settlements. This warning is given if the difference is greater than 1 % of the largest settlement value or 0.1 mm, whichever is greater.)

W420/6:

NLLOC columns in LOADATA are FLOCAL

In table LOADATA all entries in column(s) NLLOC1 (and NLLOC2) are FLOCAL

W420/7:

Soil subsidence outside pipeline.

Vertical soil subsidence has been defined outside the pipeline. Any subsidence there will be ignored..

Messages:

M420/1:

Settlement in loadata set to no soil

A soil settlement has been specified over a pipe section without soil.

(The presence of soil is governed by the specification of RVS. For pipeline sections without soil the specified settlement is ignored.)


H4204, last changed: 14/09/2016