List of generated pipe dimension data based on elements list (Output Table)

Table questioned condition:

- In case an Outer diameter/wall thickness ratio ≤ 2.0 has been found at an element and the corresponding function error has occurred, the table will become questioned. In that case the corresponding T and D/T values are indicated [Error!].

- In case a Bendradius/diameter ratio ≤ 0.5 has been found at an element and the corresponding function error has occurred, the table will become questioned. In that case the BENDPAR value is indicated [Error!].

- In case a corrosion allowance/nominal wall thickness ratio > 0.5 has been found at an element and the corresponding function error has occurred, the table will become questioned. In that case the D/T value is indicated [Error!].

Table non-production condition:

- In case a function error concerning Material name or data has occurred, the table will not be produced.

 


 

H310523, last changed: 2007-07-30

See also:

Table description

Data description/conditions