Specification of joint stiffnesses (Input Table)
Data description/conditions:
JOINTREF:
Reference name from input table PIPES
Unique name in list
TYPE:
Type of joint
Prescribed name / available types: Bellows: bellows connection
k-AX:
Axial stiffness of connection
≥ 0.
k-LAT:
Lateral (transverse) stiffness of connection
≥ 0.
k-TORS:
Torsional stiffness of connection
≥ 0.
k-ROT:
Rotational stiffness of connection
≥ 0.
OVALtype:
Indication of ring stiffness of joint construction
Prescribed names:
Stiff (no ovalisation possible)
Normal (stiffness of continuous pipe)
Free (stiffness of free pipe end)
(If Undefined (empty), the Free condition is applied.)
H330161, last changed: 9/14/2016