Specification of soil displacement in x-direction along pipeline axis (Input Table)
Data description/conditions:
X-P:
X-coordinate of data reference point
None / Required ¹
(Column may be toggled to AX-L, AX-LP, NODE, ELEM or IDENT, see toggling data tables.)
SETX1:
Soil displacement in x-direction just before and at X-P reference point
None / Required
(The value given for SETX1 on the first data line is valid for each value of X less than or equal to X-P(1). Positive SETX in positive X-direction)
UNCF1:
Uncertainty factor for soil displacement SETX1
≥ 1. / Undefined if setx1=0.
[Default: 2.0]
SETX2:
Soil displacement in x-direction just after X-P reference point
None / Undefined
(The value given for SETX2 on the last data line is valid for each value of X greater than X-P(n). See also info SETX1. If SETX2=UNDEFINED it is assumed that SETX2=SETX1.)
UNCF2:
Uncertainty factor for soil displacement SETX2
≥ 1. / Undefined
(If UNCF2=UNDEFINED it is assumed that UNFC2=UNCF1.)
SETX is multiplied by the uncertainty factor!
¹ see also table error description
H420141, last changed: 2009-07-16
See also: