List of tee stress intensification factors (Output Table)

Data description/Result options:

CONNAME:

Name of tee

TYPE:

Type of tee ¹

T-UP:

Nominal wall thickness of run or matching pipe ¹

R2-MP:

Mean radius of matching run pipe ¹

TE:

Thickness of pad or saddle ¹

(Only provided in case of REINFORCED type of tee)

R0:

Radius of curvature of external contoured portion of outlet ¹

(Only provided in case of WELDING, WELDED-IN or EXTRUDED tee)

H:

Flexibility characteristic ¹

SIX-OP:

Stress intensification factor in axial direction due to bending out of plane of tee ¹

SIX-IP:

Stress intensification factor in axial direction due to bending in plane of tee ¹

 

Info The number of rows is the number of tees specified.

¹ See table H.3 from NEN-EN 13480-3 and the notes from table E1 of Appendix E of ASME B31.8.


H500581, last changed: 9/14/2016

See also:

Table description

Table error description