Specification of number and location of partially restrained connection in a SiS section (Input Table)
Data description/conditions:
REFIDENT:
Identification name of polygon point (n)
Undefined / Existing identification
(REFIDENT should come from table ORIGIN or POLYDIF or be generated by the program)
(
REFIDENT should be positioned on the inner pipe and within the SiS section)
ΔAX-L:
Distance from polygon point (REFIDENT) along pipeline axis to the first partially restrained connection in polygon line (n)
Required / may be negative
(A negative value means a distance back towards the origin.)
(Column may be toggled to ΔX-P, ΔAX-LP, Δ Node, Δ Element or Identifier, see toggling data tables.)
N-PRC:
Number of additional partially restrained connections
> 0 / Undefined = 0
(Each PRC is located on the inner pipe and should have an accompanying outer pipe element, perpendicular from the outer pipe)
PRC-DIST:
Distance between consecutive PRCs
> 0. / Undefined if N-PRC = undefined
PRC-TYPE:
Type of partially restrained connection
Required / Prescribed names
(In the current version only 'Rollers' are allowed)
H200231, last changed: 03/05/2019
See also: