Specification of longitudinal and circumferential weld weakening factors (Input Table)

Data description/conditions:

LNGT-WELD:

Longitudinal weld affecting the normal stress in circumferential direction

(Stress components SFUBA, SFURA, SFISH/SFOSH and SFIRA/SFORA. Column not accessible.)

LW-FAC:

Weld weakening factor for LNGT-WELD stress components ¹

> 0. and ≤ 1.

[Default: 1.0]

CIRC-WELD:

Circumferential weld affecting the normal stress in longitudinal direction

(Stress components SXUB0, SXUB1, SXUBH, SXISH/SXOSH and SXIRA/SXORA Column not accessible.)

CW-FAC:

Weld weakening factor for CIRC-WELD stress components ¹

> 0. and ≤ 1.

[Default: 1.0]

 

Info Note 1 : No weakening factors are provided for TX shear stress components, because these components are zero at the inner and outer wall side, where the equivalent and principal stresses are calculated.

Info Note 2 : No weakening factors are provided for TZ full stress components, because weld imperfections are considered to occur locally only.

Info Note 3 : The weakening factors work out as stress intensification factors. Stresses are divided by their respective weakening factors.

Info Max/Min: 5/5 rows

¹ Weld weakening factors are used for equivalent, principal and uniaxial stress calculations only (tables CSTRMAX and CSTRESS)

 


 

H620131, last changed: 2007-07-30

See also:

Table description

Table error description