General design function error conditions: 19 error conditions, 5 warning conditions, 4 messages.
General error conditions: 11 error conditions, no warning condition and 2 messages.
The formatting 'xx0' of an error, warning or message indicates the design function in which the error, warning or message occurred. For example E310 indicates the error occurred in design function 3.1.
table 'title' invalid data (empty?) 3
table 'title' invalid data (no rows?) 3
table 'title' invalid data (no columns?) 3
table 'title' number of columns? 3
table 'title' toggled (system-error) 3
table 'title' n-toggled columns not correct 3
table 'title' idents SHPI not correct 3
table 'title' non exist. ident 'title'
Table 'title' empty columns not correct 3
Table 'title' second column < first 3
'Feature' not (yet) implemented
The program feature 'feature' is not yet available for customers.
Table 'title' cannot be used
The table 'title' may have correct data, but it cannot be used because e.g. model options prohibit it.
Table 'title' has no data
The mentioned table has no data in it, or it contains only untested data or data with errors.
Questioned table has errors
The table marked (see Overview Panel) contains data, during the calculation it was determined that the table has errors.
Function stopped due to occurring errors
Calculation of the design function was aborted because at least one error occurred that prohibited further calculations. See the Warning-table for more information.
Table 'title' contains data, but module 'X' is unavailable
The reported program module is not present in the user's license, but for using the data in the mentioned table this module is essential. Therefore, calculation is not possible until the user’s license is changed to contain the shown program module, or input data is changed in such a way that the mentioned table is empty.
Please contact EDS to acquire the missing program module.
Mod. 'X' unavail, can't calculate 'name'
The shown program module is not present in the user's license, but it is required to calculate the mentioned aspect of the project. Therefore, calculation of the design function is not possible until the user’s license is changed to contain the shown program module.
Please contact EDS to acquire the missing program module.
Table 'name', node 'number' does not exist ¹
Table 'name', elem 'number' does not exist ¹
Table 'name', ident 'name' doesn't exist
Tab 'name', id 'name' not in sequence
Table 'title' ignored.
No SIS, table 'title' ignored.
No tees, table 'title' ignored.
No supports, table 'title' ignored.
No joints, table 'title' ignored.
No nodal loads, table 'title' ignored.
No back tension, table 'title' ignored.
No soil, table 'title' ignored
No nonlin, table 'title' ignored
The configuration is such that the data in the mentioned table is superfluous. Therefore the data is ignored, i.e. the table is treated as if it is empty.
Mod. 'X' unavail, table 'title' ignored
The shown program module is missing in the user's license, the data in the mentioned table is ignored, i.e. the table is treated as if it is empty.
Please contact EDS to acquire the missing program module.
table 'name' idents not increasing ²
Deleted connection matrix from project.
Internal error. As a consequence the current project database might run out of available space. To avoid this situation it is advisable to create a new project, copy all input data and options to it and calculate again..
input-table(s) nd/el not in list
'Feature' not (yet) present
The program feature 'feature' is not yet available for customers. Note that this missing functionality does not influence the accuracy of the calculations results.
element table 'name' toggled to nodes ²
node table 'name' toggled to elements ²
table 'name', coordinates not in range
Specified coordinates are beyond the configuration section considered.
No core room for database+program 'tit'
Database not correct; copy tables
EDS hardware key not correct ('tittle')
Disk full; emergency exit
Educational database greater than 8 MB
Table too long for education database
Over 'number' nodes
Too many nodes due to added supports
During the element generation process a too large number of nodes is found.
Please note that the limit for the educational version is only 51 nodes. The professional version can handle up to 30000 nodes, that version will almost certainly be able to handle the current project.
Please contact EDS for more information.
Too complex for the educational version
During calculations the program has run into limitations of the educational version and can not continue. The professional version will almost certainly be able to handle the current project.
Please contact EDS for more information.
Process stopped due to no response
Wintertime hour added
Negative account changed
¹ A number of input tables contains data to be tested on conditions dependent on data calculated by the program. When, for example, input data at a node must be given, it is checked whether the node number specified is an existing node number. This check is not possible if design function 200 (GENERATE PIPELINE CONFIGURATION) has not been processed yet, because the number of nodes is calculated during processing of that function. Therefore the check is carried out during processing of the function in question.
² Through the TOGGLE option the NODE input column of tables NODALL and FOCUSL can be switched to an ELEM input column and the ELEM input columns of table SECTION can be switched to NODE columns. Those switches are ignored! IDENTS may be assigned to the same node (coordinates).
3 These are internal errors which should not occur. Please contact EDS
H2004, last changed: 27/02/2019